These are our legacy software products. For new projects click here.

Global statements

The statement

globalSettings

introduces sub-statements, which specify general parameters.

Dialog box

The sub-statement

    hotKey gui
{Shift|Lock|Control|Mod1|Mod2|Mod3|Mod4|Mod5|none}...
[key|none]

defines the hot key combination which causes the display of the graphical user interface (XposeXtool: control and configuration with graphical user interface). The default hot key combination is Shift Control.

Threads

The sub-statement

    numberOfThreads number_of_threads

specifies how many working threads the xposextool program should use for compression (Compression) (Compression). The default value of 4 is reasonable even on machines with only one single-core-processor. The special value of 0 means single tasking.

Messages

The destination of (error) messages and warnings may be specified by the sub-statement

    logDestination -|stdout|stderr|syslog|file_name

If file_name ends with .html or .htm, the messages are output in HTML format, else in plain text format. The default destination depends on the user executing the xposextool proxy program: /var/opt/XSOXposeXrecord/logs/xposextool-user_name.html.

The sub-statement

    logTypes {[+|-]statistics|none}...

configures additional output of statistical information as well as meta information (Meta data) (none by default).

Privacy Policy · Terms and conditions · Imprint/Disclaimer

Copyright © 2023 X-Software GmbH
info@x-software.com